This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| observation:2026campaign [2025/12/11 19:47] – [Available instrumentation for 2026] etienne | observation:2026campaign [2025/12/11 19:57] (current) – [Available instrumentation for 2026] etienne | ||
|---|---|---|---|
| Line 58: | Line 58: | ||
| [[technical: | [[technical: | ||
| * A slowed-down (100Hz) version of the same system can be used to stabilize Mercury. | * A slowed-down (100Hz) version of the same system can be used to stabilize Mercury. | ||
| - | * While it is not possible to use TAO over the solar limb (or for neighboring prominences), | + | * While it is not possible to use TAO over the solar limb (or for neighboring prominences), |
| === MTR2 in spectroscopy mode === | === MTR2 in spectroscopy mode === | ||
| In this mode, up to 4 (old) EMCCD Andor iXon camera (512x512) and up to 2 (new) Andor Zyla (2kx2k) cameras are available. Both 6 cameras can be setup and used at the same time (with their respective specs), | In this mode, up to 4 (old) EMCCD Andor iXon camera (512x512) and up to 2 (new) Andor Zyla (2kx2k) cameras are available. Both 6 cameras can be setup and used at the same time (with their respective specs), | ||
| [[technical: | [[technical: | ||
| - | * Reconstructed maps quick-look softwares are available for on site analysis. | ||
| - | |||
| === MTR2 in spectropolarimetry mode: === | === MTR2 in spectropolarimetry mode: === | ||
| Line 70: | Line 68: | ||
| Regarding the available analysis software: | Regarding the available analysis software: | ||
| - | | + | |
| - | * Thanks to V. Bommier, a basic magnetic field inversion software package (running locally in IDL) is available. | + | |
| === Broadband imaging context camera: === | === Broadband imaging context camera: === | ||
| THEMIS BBI fast camera (40 frames/s) is running concurrently with the spectrograph. Current setup is for 656 nm (red), but can be changed optionally to G-band or other. | THEMIS BBI fast camera (40 frames/s) is running concurrently with the spectrograph. Current setup is for 656 nm (red), but can be changed optionally to G-band or other. | ||
| + | |||
| + | === Available analysis softwares === | ||
| + | |||
| + | * Knox Thompson image reconstruction for BBI | ||
| + | * Reconstructed spectral map quick-looks for on site analysis, to be adapted to specific wavelength. | ||
| + | * Stokes map quick-looks | ||
| + | * Thanks to V. Bommier, a basic magnetic field inversion software package (running locally in IDL) is also available. | ||
| + | |||
| /* == 2024 known problems (and solutions) == | /* == 2024 known problems (and solutions) == | ||