Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
technical:mtr2 [2026/06/30 09:33] – etiennetechnical:mtr2 [2026/09/28 15:41] (current) – [Schematics of MTR2] saida
Line 12: Line 12:
 The following table present typical values of the MTR2 spectral resolution, δλ, for different wavelength and F2 entrance slit width.  The following table present typical values of the MTR2 spectral resolution, δλ, for different wavelength and F2 entrance slit width. 
  
-^  MTR2 entrance  ^  Wavelength  ^^^^^ +|              |              ^  Wavelength  ^^^^^ 
-^  slit width     ^  4861.3 Å  (Hβ)  ^  5250.0 Å (Fe I doublet)  ^  5875.7 Å (He I D3)  ^ 6302.0 Å (Fe I doublet) ^ 6562.8 Å (Hα)  ^ +|  :::         |  :::         ^    Hβ      ^  Fe I doublet  ^   He I D3  ^  Fe I doublet  ^  Hα        ^ 
-|  0.5"           |  19 mÅ           |  23 mÅ                    |  28 mÅ               |   26 mÅ                 |  31 mÅ         | +|  :::         |  :::         ^  4861.3 Å  ^  5250.0 Å      ^  5875.7 Å  ^  6302.0 Å      ^  6562.8 Å  ^ 
-|  0.3"           |  12 mÅ           |  14 mÅ                    |  17 mÅ               |   17 mÅ                 |  20 mÅ         | +^  MTR2        ^  0.5"        |  19 mÅ     |  23 mÅ         |  28 mÅ     |   26 mÅ        |  31 mÅ     | 
-|  0.1"           |   6 mÅ           |   7 mÅ                    |   9 mÅ               |    9 mÅ                 |  10 mÅ         |+^  entrance    ^  0.3"        |  12 mÅ     |  14 mÅ         |  17 mÅ     |   17 mÅ        |  20 mÅ     | 
 +^  slit width  ^  0.1"        |   6 mÅ     |   7 mÅ         |   9 mÅ     |    9 mÅ        |  10 mÅ     |
  
  
Line 31: Line 32:
 The moving parts are:  The moving parts are: 
   * The predisperser gratings selection table (EM35). There are 3 selectable predispersers, although only one (the central slot) is mainly used for MTR2 operation.    * The predisperser gratings selection table (EM35). There are 3 selectable predispersers, although only one (the central slot) is mainly used for MTR2 operation. 
-  * PThe predisperser rotates about the Y axis to change its grating incidence angle (EM37). This allows shifting  the lowres spectrum along Z over the masks stop plate. +  * The predisperser rotates about the Y axis to change its grating incidence angle (EM37). This allows shifting  the lowres spectrum along Z over the masks stop plate. 
   * The mask plate translates in the  Z direction (EM39)   * The mask plate translates in the  Z direction (EM39)
   *  The echelle grating rotates about the Y axis to change its grating incidence angle a (EM32). This allows shifting the highres spectrum along Z at the SP2 output.   *  The echelle grating rotates about the Y axis to change its grating incidence angle a (EM32). This allows shifting the highres spectrum along Z at the SP2 output.
Line 44: Line 45:
        * manual setup of the spectral cameras at the SP2 output        * manual setup of the spectral cameras at the SP2 output
 Data and formulae for the MTR2 can be found in the following document: \\ Data and formulae for the MTR2 can be found in the following document: \\
- [[this>wdata/WSpectroTools/Spectro_Formulae.pdf | THEMIS spectrograph (auth: CLM)]]+ [[this>wdata/WSpectroTools/Spectro_Formulae.pdf | THEMIS spectrograph ]] (author: Claude Le Mein).
  
 ==== Spectrograph simulation tools  ==== ==== Spectrograph simulation tools  ====
 These tools allow the observer to quick check the feasibility of a setup These tools allow the observer to quick check the feasibility of a setup
-  * [[this>wdata/Instrument/tools/Rep1/MtrSim.html | MTR spectrograph simulator]] (java web version / auth: CLM) +  * [[this>wdata/Instrument/tools/Rep1/MtrSim.html | MTR spectrograph simulator]] (java web version / author: Claude Le Mein) 
-  * [[this>wdata/WSpectroTools/MTR_Calculator.xls | MTR spectrograph simulator]] (Downloadable excel version / auth: CLM)\\ Please enable macros to get a correct result.+  * [[this>wdata/WSpectroTools/MTR_Calculator.xls | MTR spectrograph simulator]] (Downloadable excel version / author: Claude Le Mein)\\ Please enable macros to get a correct result.
  
 Observers can also check the  [[technical:mtr2:maskplates| list of existing available mask plates]] to have an idea of readily available combination. Observers can also check the  [[technical:mtr2:maskplates| list of existing available mask plates]] to have an idea of readily available combination.
technical/mtr2.1782812007.txt.gz · Last modified: by etienne