Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
technical:mtr2 [2026/06/30 09:46] – [MTR2 spectral resolution] etiennetechnical:mtr2 [2026/09/28 15:41] (current) – [Schematics of MTR2] saida
Line 12: Line 12:
 The following table present typical values of the MTR2 spectral resolution, δλ, for different wavelength and F2 entrance slit width.  The following table present typical values of the MTR2 spectral resolution, δλ, for different wavelength and F2 entrance slit width. 
  
-^  MTR2        ^  Wavelength  ^^^^^ +|              |              ^  Wavelength  ^^^^^ 
-^  entrance    ^  4861.3 Å  ^  5250.0 Å        ^  5875.7 Å  ^  6302.0 Å        ^  6562.8 Å  ^ +|  :::         |  :::         ^    Hβ      ^  Fe I doublet  ^   He I D3  ^  Fe I doublet  ^  Hα        ^ 
-^  slit width  ^  (Hβ)      ^  (Fe I doublet)  ^  (He I D3) ^  (Fe I doublet)  ^  (Hα)      ^ +|  :::         |  :::         ^  4861.3 Å  ^  5250.0 Å      ^  5875.7 Å  ^  6302.0 Å      ^  6562.8 Å  ^ 
-|  0.5"        |  19 mÅ     |  23 mÅ           |  28 mÅ     |   26 mÅ          |  31 mÅ     | +^  MTR2        ^  0.5"        |  19 mÅ     |  23 mÅ         |  28 mÅ     |   26 mÅ        |  31 mÅ     | 
-|  0.3"        |  12 mÅ     |  14 mÅ           |  17 mÅ     |   17 mÅ          |  20 mÅ     | +^  entrance    ^  0.3"        |  12 mÅ     |  14 mÅ         |  17 mÅ     |   17 mÅ        |  20 mÅ     | 
-|  0.1"        |   6 mÅ     |   7 mÅ           |   9 mÅ     |    9 mÅ          |  10 mÅ     |+^  slit width  ^  0.1"        |   6 mÅ     |   7 mÅ         |   9 mÅ     |    9 mÅ        |  10 mÅ     |
  
  
Line 32: Line 32:
 The moving parts are:  The moving parts are: 
   * The predisperser gratings selection table (EM35). There are 3 selectable predispersers, although only one (the central slot) is mainly used for MTR2 operation.    * The predisperser gratings selection table (EM35). There are 3 selectable predispersers, although only one (the central slot) is mainly used for MTR2 operation. 
-  * PThe predisperser rotates about the Y axis to change its grating incidence angle (EM37). This allows shifting  the lowres spectrum along Z over the masks stop plate. +  * The predisperser rotates about the Y axis to change its grating incidence angle (EM37). This allows shifting  the lowres spectrum along Z over the masks stop plate. 
   * The mask plate translates in the  Z direction (EM39)   * The mask plate translates in the  Z direction (EM39)
   *  The echelle grating rotates about the Y axis to change its grating incidence angle a (EM32). This allows shifting the highres spectrum along Z at the SP2 output.   *  The echelle grating rotates about the Y axis to change its grating incidence angle a (EM32). This allows shifting the highres spectrum along Z at the SP2 output.
technical/mtr2.1782812785.txt.gz · Last modified: by etienne
Recent changes RSS feed Debian Powered by PHP Valid XHTML 1.0 Valid CSS Driven by DokuWiki