Line 13: Line 13:
  
 |              |              ^  Wavelength  ^^^^^ |              |              ^  Wavelength  ^^^^^
-|  :::         |  :::         ^  4861.3 Å  ^  5250.0 Å        ^  5875.7 Å  ^  6302.0 Å        ^  6562.8 Å  ^ +|  :::         |  :::         ^    Hβ      ^  Fe I doublet  ^   He I D3  ^  Fe I doublet  ^  Hα        ^ 
-|  :::         |  :::         ^  (Hβ)      ^  (Fe I doublet)  ^  (He I D3) ^  (Fe I doublet)  ^  (Hα)      ^ +|  :::         |  :::         ^  4861.3 Å  ^  5250.0 Å      ^  5875.7 Å  ^  6302.0 Å      ^  6562.8 Å  ^ 
-^  MTR2        ^  0.5"        |  19 mÅ     |  23 mÅ           |  28 mÅ     |   26 mÅ          |  31 mÅ     | +^  MTR2        ^  0.5"        |  19 mÅ     |  23 mÅ         |  28 mÅ     |   26 mÅ        |  31 mÅ     | 
-^  entrance    ^  0.3"        |  12 mÅ     |  14 mÅ           |  17 mÅ     |   17 mÅ          |  20 mÅ     | +^  entrance    ^  0.3"        |  12 mÅ     |  14 mÅ         |  17 mÅ     |   17 mÅ        |  20 mÅ     | 
-^  slit width  ^  0.1"        |   6 mÅ     |   7 mÅ           |   9 mÅ     |    9 mÅ          |  10 mÅ     |+^  slit width  ^  0.1"        |   6 mÅ     |   7 mÅ         |   9 mÅ     |    9 mÅ        |  10 mÅ     |
  
  
Line 32: Line 32:
 The moving parts are:  The moving parts are: 
   * The predisperser gratings selection table (EM35). There are 3 selectable predispersers, although only one (the central slot) is mainly used for MTR2 operation.    * The predisperser gratings selection table (EM35). There are 3 selectable predispersers, although only one (the central slot) is mainly used for MTR2 operation. 
-  * PThe predisperser rotates about the Y axis to change its grating incidence angle (EM37). This allows shifting  the lowres spectrum along Z over the masks stop plate. +  * The predisperser rotates about the Y axis to change its grating incidence angle (EM37). This allows shifting  the lowres spectrum along Z over the masks stop plate. 
   * The mask plate translates in the  Z direction (EM39)   * The mask plate translates in the  Z direction (EM39)
   *  The echelle grating rotates about the Y axis to change its grating incidence angle a (EM32). This allows shifting the highres spectrum along Z at the SP2 output.   *  The echelle grating rotates about the Y axis to change its grating incidence angle a (EM32). This allows shifting the highres spectrum along Z at the SP2 output.